The 6-heads ampoule
filling and sealing machine AGF is more suitable for the
technological requirements of water and powder injections. It
features high capacity, good quality, stable operation, and so
it is ideal equipment for ampoule medicine production.
l
Upside of the ampoule filling and sealing machine is set of one hundred
stage laminar flow purify in protection.
l There
is set to prevent from filling on filling and sealing machine
l
Liquefaction gas and oxygen is adopted as filling burning gas on
Filling and sealing machine.
l Stand-rotation sealing is adopted on Filling
and sealing machine,
sealing quality is good.
l Tiny-adjustment is adopted for filling on filling
and sealing
machine; error is smaller in filling value.
l Under
the control of buffer, filling and sealing machine can mater with
production.
Operating Theory
Ampoule-bottles are putted into passage for bottle entrance in bulk by
the transmission belt of AGF mold 6-heads ampoule filling and sealing
machine, under the control of barrier six ampoule-bottles are
segregated every time, then carried to filling unit and stealing
by teeth-plate in interval. The filling and stealing is under
the protect of one hundred stage lamina flow. Sealed
ampoule-bottle is putted outside bottle-pusher.
Technical Data:
1.
Power: 380V, 50Hz
2.
Gross power of motor: 1.5kw
3.
Volume of liquid gas: 1.2m3/h
4.
Volume of oxygen gas: 0.6m3/h
5.
Speed control: 30 ~ 36 r/min (staples speed adjustment).
6.
Weight: about 1400kg
7.
Overall size (length * width * height): 2500*1200*2250m
Output:
Ampoule: 1ml: 11500-pcs/h, 2ml: 11500 pcs/h, 5ml: 10000 pcs/h, 10ml: 8000pcs/h, 20ml: 6000 pcs/h
Operating procedure
l Before
starting up, washing the filling pump, sampling and test, the
clarity must be accord with the standard specified by the
pharmacopoeia.
l Adjust
the pump stroke with a fine-regulating bolt, until get the best
stroke, then adjust the dosage with fine regulation switch, make it
up to standard and without any dripping.
l Set the
fillers’ position correctly in order to avoid I touching ampoule
neck.
l Before
ignition, make sure that oxygen, nitrogen, liquefied, natural gas
and the air for suction is enough. Fist, open the burning gas valve,
then open the oxygen valve and adjust the valve to have fire
properly. Before stop machine, should turn off the oxygen valve.
After about a minute, close the gas to prevent the return fire
burning down the tubes.